SGT-110PL

SGT-110PL

Engine : PERKINS
Alternator : Leroy Somer


Standby
110 kVA
Prime
100 kVA
Frequency
50
Voltage
400/231
Phase
3
Cos φ
0.8 kVA
SGT-110PL

Technical Features


Engine Specifications

Engine Brand
PERKINS
Engine Model
1104C-44TAG2
Standby Power (Kw/hp)
103 /138,1
Engine Speed (r.p.m)
1500
Total Displacement (L)
4.41
Cylinder Arrangement
4-L
Bore x Stroke (mm x mm)
105 x 127
Compretion Ratio
18,2:1
Governor Type
Electronic
Aspiration System
Turbocharged AAC
Injection
Direct
Cooling System
Water Cooled
Electrical System (VDC)
12
Oil Capacity (L)
8
Coolant Capacity (L)
12.6
Fuel Tank Capacity (L)
180
Maximum Exhaust Gas Temperature (°C)
543
Maximum Exhaust Gas Flow (m3/h)
978
Maximum Back Pressure (kPa)
18
Cooling Air Flow (m3/min)
165.6
Fuel Consumption at 50 % (L/h)
11.8
Fuel Consumption at 75 % (L/h)
17.1
Fuel Consumption at 100 % (L/h)
22.6
Cylinder Liner Type
Wet Type-Replacable
Air Filter Type
Dry Type-Replacable
Radiator
Tropical type up to 50 °C

Alternator Specifications

Alternator Brand
Leroy Somer
Alternator Model
TAL044 D
Frequency (Hz)
50
Nominal Power (kVA)
100
Nominal Voltage (V)
400
Phase
3
Regulated By
AVR
Voltage Regulation
± 1 %
Short Circuit Current
100% In
Insulation
Class H
IP Class
IP 23
Power Factor
0.8
Efficiency (%)
90.8
THD
< 2 %
Connection Type
Star connection
Number of Wires
6
Poles
4 pole
Bearing Type
Single Bearing

Open Type Dimensions and Weight

Width (mm)
1100
Length (mm)
2000
Height (mm)
1552
Weight (Kg)
1135
Fuel Tank Capacity (L)
180

Canopy Type Dimensions and Weight

Width (mm)
1100
Length (mm)
2850
Height (mm)
1802
Weight (Kg)
1500
Fuel Tank Capacity (L)
180